PYROCHEM
The PYRO-CHEM KITCHEN KNIGHT II Pre-Engineered System utilizes a wet chemical agent specifically designed to suppress restaurant cooking area fires. The system provides automatic actuation and can be manually actuated through a remote mechanical pull station. Upon actuation, the system discharges a pre-determined amount of agent to the duct, plenum, and cooking appliances. The agent acts to suppress fires in three ways:
1-The chemical chain reaction causing combustion is interrupted by both the agent itself and the resulting steam formation.
2-The agent cools the fire bringing it below auto-ignition temperature.
3-The agent reacts with hot grease forming a soap-like layer (saponification) that helps prevent the escape of combustible vapors, thus preventing re-ignition.
The shutdown of all sources of fuel and electric power that produce heat to all equipment protected by the system is required upon system actuation. Make up or supply air fans, Integral to the exhaust hood(s) being protected shall be shut down upon system actuation. Exhaust fan(s) in the ventilation system should remain on during system discharge as They assist the dispersion of chemical through the ventilating system. The system is UL Listed with or without exhaust fan shutdown.
Data sheet
Data sheet
The KITCHEN KNIGHT II system offers breakthrough technology in the industry's most flexible and effective suppression system
- Extended Coverage
- Enhanced Components
- Nozzles
- Only five nozzles to inventory
- Full cone spray
- Individual swivel adaptors
- High and low proximity ranges from 13 to 50 inches (330 to 1270 mm)
- Chrome caps help protect against contamination and blockage
- Cylinders
- 10,15, and 20 flow cylinders offer more coverage
- Improved Piping Flexibility
- Incorporates ¼" to ¾" pipe
- Simple piping rules
- Back Shelf Protection
The fire extinguishing agent is a potassium carbonate-based water solution that knocks the flame down, cuts off air to the burning grease and cools the hazard area to help ensure the fire stays out. The KITCHEN KNIGHT II system has been tested and approved in accordance with the UL testing standard for kitchen cooking areas, Standard UL-300. Pyro-Chem authorized distributors have been extensively trained in system design, installation and maintenance. Pyro-Chem continues to perform extensive research and development on KITCHEN KNIGHT II system components. Continuous improvements to virtually every aspect of the system provide affordable, effective protection for the cooking area